Add water and mix manually or mechanically until a smooth, workable consistency is obtained.
Let the mixture rest for 5 minutes and mix again.
When installing ceramic tiles, this is done traditionally, rocking each tile well. Better adhesion is achieved by first spreading a thin, compact layer on the brick with a trowel.
When installing wall coverings, add the product to the substrate by spreading it with a trowel. For large-format tiles, use a double-bonding system.
Respect construction joints (expansion, contraction, splitting, perimeter corner joints) as well as the joints between tiles (minimum 2 mm).
The joints should be filled after 24-48 hours, depending on the thickness of the adhesive used. Use mortar from the RITAL JOINT COMPUND RANGE, depending on the type of joint.
Precautions and Recommendations
Do not use below 5ºC or above 30ºC.
Do not use in areas with a risk of frost, rain, strong winds, or direct sunlight.
Do not use in areas at risk of standing water.
For claddings over 30 m², leave expansion joints filled with a deformable material.
For interior claddings with an area over 15 m², it is recommended to leave a perimeter expansion joint between the cladding and the wall or pillar located behind the recessed base.
To ensure perfect adhesion, avoid moving the tiles over the tiles for 3 or 4 days.
Maximum weight for vertical cladding: 40 kg/m².
On facades and exterior walls, the material should always be installed using anchors or mechanical fixing.