ADHESIVE CEMENT C1

Add water and mix manually or mechanically until a smooth, workable consistency is obtained.

Let the mixture rest for 5 minutes and mix again.

When installing ceramic tiles, this is done traditionally, rocking each tile well. Better adhesion is achieved by first spreading a thin, compact layer on the brick with a trowel.

When installing wall coverings, add the product to the substrate by spreading it with a trowel. For large-format tiles, use a double-bonding system.

Respect construction joints (expansion, contraction, splitting, perimeter corner joints) as well as the joints between tiles (minimum 2 mm).

The joints should be filled after 24-48 hours, depending on the thickness of the adhesive used. Use mortar from the RITAL JOINT COMPUND RANGE, depending on the type of joint.

 

Precautions and Recommendations

Do not use below 5ºC or above 30ºC.

Do not use in areas with a risk of frost, rain, strong winds, or direct sunlight.

Do not use in areas at risk of standing water.

For claddings over 30 m², leave expansion joints filled with a deformable material.

For interior claddings with an area over 15 m², it is recommended to leave a perimeter expansion joint between the cladding and the wall or pillar located behind the recessed base.

To ensure perfect adhesion, avoid moving the tiles over the tiles for 3 or 4 days.

Maximum weight for vertical cladding: 40 kg/m².

On facades and exterior walls, the material should always be installed using anchors or mechanical fixing.

 

  • Add water and mix manually or mechanically until a smooth, workable consistency is obtained.

    Let the mixture rest for 5 minutes and mix again.

    When installing ceramic tiles, this is done traditionally, rocking each tile well. Better adhesion is achieved by first spreading a thin, compact layer on the brick with a trowel.

    When installing wall coverings, add the product to the substrate by spreading it with a trowel. For large-format tiles, use a double-bonding system.

    Respect construction joints (expansion, contraction, splitting, perimeter corner joints) as well as the joints between tiles (minimum 2 mm).

    The joints should be filled after 24-48 hours, depending on the thickness of the adhesive used. Use mortar from the RITAL JOINT COMPUND RANGE, depending on the type of joint.

     

    Precautions and Recommendations

    Do not use below 5ºC or above 30ºC.

    Do not use in areas with a risk of frost, rain, strong winds, or direct sunlight.

    Do not use in areas at risk of standing water.

    For claddings over 30 m², leave expansion joints filled with a deformable material.

    For interior claddings with an area over 15 m², it is recommended to leave a perimeter expansion joint between the cladding and the wall or pillar located behind the recessed base.

    To ensure perfect adhesion, avoid moving the tiles over the tiles for 3 or 4 days.

    Maximum weight for vertical cladding: 40 kg/m².

    On facades and exterior walls, the material should always be installed using anchors or mechanical fixing.

     

    • Comment utiliser:

      Presentation

      25 kg laminated paper bags.

      Storage for up to 1 year in the original packaging, protected from weather and humidity.

      Technical Data

      (Statistical results obtained under standard conditions)

       

      Appearance:                                                                 WHITE or GREY

      Mixing water for white product:                                     24 ± 2%

      Mixing water for gray product:                                       27.5 ± 2%

      Apparent dust density:                                                  1.5 ± 0.2 g/cm3

      Mixed product density:                                                    1.8 ± 0.2 g/cm3

      Adjustment time:                             Approximately 30 minutes (depending on climatic conditions)

      Paste pot life:                          Approximately 2 hours (Depending on climatic conditions)

      Initial adhesion                                                                                 > 0.5 N/mm²

      Adhesion after water exposure                                                      > 0.5 N/mm²

      Adhesion after aging under heat                                                    > 0.5 N/mm²

      Adhesion after freeze-thaw cycle                                                    > 0.5 N/mm²

      Classification according to NF EN 12004:                                            2001 C1 T

      Approximate coverage                                                 15 kg/m² per cm of thickness

      Application thickness:                                          Allowable between 0.5 and 2 cm

       

       

      Note

      The instructions in this manual are based on our tests and knowledge, and do not imply any commitment on the part of SARL RITAL or release the consumer from the responsibility of checking and verifying the products for their correct use. Claims must be accompanied by the original packaging to allow for proper traceability.

       

      SARL RITAL assumes no responsibility, under any circumstances, for the application of its products or construction solutions by the application company or other parties involved in the application and/or execution of the project in question. RITAL's liability is limited exclusively to possible damages directly or exclusively attributable to the products supplied, individually or integrated into systems, due to manufacturing defects.